SDS6000A Firmware Update
バージョン
V1.4.9.5
SDS6000 Firmware Update
バージョン
V1.4.9.3
2024-04-23
バージョンの説明
1. Supported new probes: Siglent’s SCP5030, SCP5030A, SCP5150, SCP5500 and LeCroy’s CP150, HVD3106A
2. Option to hide Memory and Math traces
3. Webserver: Screenshot can be directly copied and pasted
4. Fixed several bugs
a) Decode Threshold bug
b) NO persistence available with frames captured by SEQUENCE
2. Option to hide Memory and Math traces
3. Webserver: Screenshot can be directly copied and pasted
4. Fixed several bugs
a) Decode Threshold bug
b) NO persistence available with frames captured by SEQUENCE
SDS6000 Firmware Update
バージョン
V1.4.5.2
2023-11-09
バージョンの説明
- Eye Diagram: supported 100Base-T1 (PAM3)
- SCPI: Supported Search
- Supported USB-GPIB
- Fixed several bugs
- DY-WTFK-202203165613:Spectrum menu after installing
- DY-WTFK-202209237014: Scope restarts acquisition after few seconds when stopped
- DY-WTFK-202207076348: Filter settings way off in special acquisition modes
- DY-WTFK-202209237015: Zone trigger doesn’t work at some input frequencies
SDS6000 Firmware Update
バージョン
V1.4.4.1
2023-11-09
バージョンの説明
1. Force trigger strategy changed (same as SDS2000X HD)
2. Save/Recall
a.Supported to save all sequence segments
b. Supported Auto Save
3. Fixed several bugs
a.Cannot communicate with the SDG2000X and SDG7000A over USB in Bode Plot
b.Random +/-200 ps skew between channels after power/reboot cycle
c.[Power analysis] - Switching losses - Error in calculations
d.FFT wrong vertical scale
4. Memory channel trace always on top
2. Save/Recall
a.Supported to save all sequence segments
b. Supported Auto Save
3. Fixed several bugs
a.Cannot communicate with the SDG2000X and SDG7000A over USB in Bode Plot
b.Random +/-200 ps skew between channels after power/reboot cycle
c.[Power analysis] - Switching losses - Error in calculations
d.FFT wrong vertical scale
4. Memory channel trace always on top
SDS6000 Firmware Update
バージョン
V1.4.3.3
2023-11-09
バージョンの説明
Note: This release cannot be downgraded to former releases.
- Math: added filter operator
- Supported to save waveform as Memory traces, which store the raw data instead of the screen data (as Ref does), and can be source of Measure/Math etc.
- Measure: improved the AIM limit from 1,000 to up to 65,000 (AIM limit: the upper limit of horizontal parameters measure statistics in one frame )
- Optimized intensity display of math traces.
- Added support for mouse wheel when using a mouse
- Supported CP030 current probe (with LPA10 adapter)
- Eye Diagram: 100Base-TX signal supported
- Trigger: Pattern trigger strategy changed
- Power Analysis:
- Supported MOSFET SOA (Safe Operating Area)
- Bigger table size
- Fixed several bugs
- Moving the traces by gestures may cause the scope to freeze
- [Bode Plot]Vertical Ref.level manual setting is partially bad
- [Measure]Track plot - not working well in general
- [Power Analysis]Current harmonics forgets table/bar view
- Waveform Capture Rate breakdown at 20 ns/div
SDS6000 Firmware Update
バージョン
V1.4.0.0
SDS6000 Firmware Update
バージョン
V1.3.9.0
SDS6000 Firmware Update
バージョン
V1.4.8.3
バージョンの説明
バージョンの説明